Step | Action | Yes | No |
---|---|---|---|
1 | Did you review the Charging System Description and the Charging System Circuit Description and perform the necessary inspections? | Go to Step 2 | |
2 | Verify that the charge indicator is always on. Is the charge indicator always on? | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |
3 |
Does the charge indicator light? | Go to Step 5 | Go to Step 4 |
4 | Repair or replace the generator. Refer to Generator Replacement and Generator Overhaul . Is the repair complete? | Go to Step 10 | -- |
5 |
Does the charge indicator light? | Go to Step 7 | Go to Step 6 |
6 | Replace the DRL control module. Refer to Daytime Running Lights (DRL) Control Module Replacement in Lighting Systems. Is the repair complete? | Go to Step 10 | -- |
7 | Test for a short to ground in the WHT/RED wire between the instrument panel cluster and the generator. Is a short to ground present? | Go to Step 8 | Go to Step 9 |
8 | Repair the short. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 10 | -- |
9 | Repair or replace the instrument cluster printed circuit. Is the repair complete? | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |