Refer to
Fuel Supply System Flow
The powertrain control module (PCM) will energize the fuel pump relay for 3 seconds when the ignition switch is turned to the ON position. The fuel pump will operate and pressurize the fuel system when the fuel pump relay is energized. The PCM receives ignition system reference pulses when the engine is being cranked or when the engine is running. The PCM will continue to energize the fuel pump relay as long as the PCM receives ignition system reference pulses. The PCM will de-energize the fuel pump relay when ignition system reference pulses are no longer detected.
The fuel supply system delivers fuel to the fuel injectors at a controlled pressure. The controlled fuel pressure is 250-300 kPa (36-43 psi) when the fuel pump is energized and the engine is not running. The controlled fuel pressure is 210-260 kPa (30-37 psi) when the engine is idling at normal operating temperatures. The fuel pressure regulator maintains the correct fuel pressure at all times by returning excess fuel to the fuel tank.
Improper fuel system pressure can result in any of the following conditions:
• | The engine cranks but will not start |
• | The engine cuts out or stalls (may feel like an ignition malfunction) |
• | A decrease in fuel economy and a decrease in power |
• | Hard starting |
One minute after the fuel pump stops, the fuel pressure should hold at approximately 180 kPa (25 psi) or more.
An intermittent malfunction may be caused by a problem in the fuel pump electrical circuit. Inspect the wiring harness and components for any of the following conditions:
• | Any backed-out terminals |
• | Any improper mating of terminals |
• | Any broken electrical connector locks |
• | Any improperly formed or damaged terminals |
• | Any faulty terminal-to-wire connections |
• | Any physical damage to the wiring harness |
• | A broken wire inside the insulation |
• | Any corrosion of the electrical connections, the splices, or the terminals |
The numbers below refer to the step numbers in the diagnostic table.
The Powertrain OBD System Check prompts the technician to complete some basic checks and to store the Freeze Frame data on the scan tool if applicable. This creates an electronic copy of the data taken when the fault occurred. The information is then stored in the scan tool for later reference.
This step checks to see if fuel system pressure is within specifications with the ignition On and the fuel pump running. The fuel pump may be operated with the scan tool Output Control feature when the fuel level is more than 20 percent and no DTCs are set.
This step checks the fuel pressure after the fuel pump stops. Approximately one minute after the fuel pump stops fuel pressure should remain steady above 180 kPa (25 psi). The fuel pump may be operated with the scan tool Output Control feature when the fuel level is more than 20 percent and no DTCs are set.
The vehicle should start and run. At this step, adequate fuel pressure is available for the engine to operate. A vehicle that will not start may have inoperable fuel injectors.
This step checks for normal fuel pressure when the engine is running. Fuel pressure that is not within the specified value indicates a possible fault in the fuel pressure regulator.
This step checks for a faulty check valve in the fuel pump. Blocking (pinching) the fuel feed hose between the fuel pressure gauge and the fuel pump, immediately after the fuel pump stops, traps the fuel pressure between the fuel pressure regulator and the blocked section. If fuel pressure now remains above the specified value, the fault is between the blocked section and the fuel tank. The fuel pump may be operated with the scan tool Output Control feature when the fuel level is more than 20 percent and no DTCs are set.
This step checks for a faulty fuel pressure regulator. You may operate the fuel pump with the scan tool Output Control feature when the fuel level is more than 20 percent and no DTCs are set.
A fault in the fuel pump electrical circuit may cause low fuel pressure or no fuel pressure.
This step checks for additional conditions that can cause low fuel pressure other than a faulty fuel pump. Check for any restrictions or blockage in the fuel feed lines and hoses, including those inside the fuel tank. Check the fuel pump electrical circuit for excessive resistance. Proper fuel pump operation requires correct voltage and adequate current flow.
This step checks the operation of the fuel pressure regulator. You may operate the fuel pump with the scan tool Output Control feature when the fuel level is more than 20 percent and no DTCs are set.
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Did you perform the Powertrain On-Board Diagnostic (OBD) System Check? | -- | |||||||||
2 |
Was there any fuel pressure indicated? | -- | ||||||||
Important: In order to obtain maximum fuel pressure it may be necessary to cycle the ignition ON to OFF to ON more than once. Is the fuel pressure indicated within the specified values? | 250-300 kPa (36-43 psi) | |||||||||
Does the fuel pressure hold at or above the specified value? | 180 kPa (25 psi) | |||||||||
Start the engine. Does the vehicle start and run? | -- | |||||||||
Run the engine to normal operating temperature. Is the fuel pressure indicated within the specified values? | 210-260 kPa (30 - 37 psi) | System OK | ||||||||
7 |
Was a repair necessary? | -- | ||||||||
Does the fuel pressure hold at or above the specified value? | 180 kPa (25 psi) | |||||||||
Does the fuel pressure remain at or above the specified value? | 180 kPa (25 psi) | |||||||||
10 |
Is the action complete? | -- | -- | |||||||
11 | Is the fuel pressure below the specified value? | 250 kPa (36 psi) | ||||||||
12 |
Important: In order to obtain maximum fuel pressure it may be necessary to cycle the ignition ON to OFF to ON more than once.
Is the fuel pressure at the specified value or higher? | 400 kPa (57 psi) | ||||||||
Was the fuel pump relay diagnostic procedure performed? | -- | |||||||||
Was a repair necessary? | -- | |||||||||
Is the fuel pressure within the specified value? | 250-300 kPa (36-43 psi) | |||||||||
16 | Repair or replace the restricted fuel return pipe or hose. Is the action complete? | -- | -- | |||||||
17 | Replace the fuel pressure regulator. Refer to Fuel Pressure Regulator Replacement . Is the action complete? | -- | -- | |||||||
18 | Replace the fuel pump. Refer to Fuel Sender Assembly Replacement . Is the action complete? | -- | -- | |||||||
19 | Operate the vehicle within the conditions under which the original symptom was noticed. Does the system now operate properly? | -- | System OK | Go to Diagnostic Aids |