Removal Procedure
- Remove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement
.
- Remove the intake manifold cover. Refer to
Intake Manifold Cover Replacement
.
- Disconnect the engine wiring harness electrical connector (1) from the exhaust camshaft position (CMP)
sensor.
- Remove the exhaust CMP sensor bolt. (Intake CMP shown, exhaust CMP similar).
- Remove the exhaust CMP sensor.
Installation Procedure
Important: Inspect the exhaust CMP sensor for damage, replace as necessary.
- Lubricate the exhaust CMP sensor O-ring seal with clean engine oil.
- Install the exhaust CMP sensor. (Intake CMP shown, exhaust CMP similar).
Notice: Refer to Fastener Notice in the Preface section.
- Install the exhaust CMP sensor bolt.
Tighten
Tighten the bolt to 10 N·m (89 lb in).
- Connect engine wiring harness electrical connector (1) to the exhaust CMP sensor.
- Install the intake manifold cover. Refer to
Intake Manifold Cover Replacement
.
- Install the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement
.