Battery voltage is supplied directly to the after blow relay directly through the underhood fuse block. The body control module (BCM), provides the ground to enable the after blow operation through the blower motor relay control circuit. The after blow relay control circuit and relay are retailer installed. The BCM provides logic to enable the blower based on information from the engine control module (ECM) or powertrain control module (PCM). The duration of the after blow relay cycle is determined by A/C operation, ambient air temperature and vehicle speed.
• | Engine is running. |
• | Any of the conditions for setting the DTC are met for 5 seconds. |
• | Battery voltage is between 11 to 18 volts. |
• | Output control is OFF. |
• | Output control is ON. |
• | The BCM will not illuminate the malfunction indicator lamp (MIL). |
• | The BCM stores the Failure Records. |
• | The HVAC blower is disabled. |
• | The history DTC will clear after forty consecutive ignition cycles have occurred without a malfunction. |
• | The DTC can be cleared by the scan tool. |
• | The DTC will become history if the BCM no longer detects a failure. |
• | Visually inspect the relay and connection for damage. |
• | Visually inspect the instrument panel fuse block for damage. |
• | Check for poor connection at the BCM. |
• | Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. |
The numbers below refer to the step numbers on the diagnostic table.
Listen for an audible click when the after blower relay operates. Command both the ON and OFF states. Repeat the commands as necessary.
Tests for voltage at the coil side of the after blow relay. The BATT Feed fuse supplies power to the coil side of the after blow relay.
Verifies that the body control module is providing ground to the after blow relay.
Tests if ground is constantly being applied to the after blow relay.
Tests if intermittent voltage is being applied to the after blow relay.
It is important to follow the programming procedure for replacing the body control module.
Step | Action | Yes | No |
---|---|---|---|
Connector End View Reference: HVAC Connector End Views | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
Does the after blow relay turn ON and OFF with each command? | Go to Diagnostic Aids | Go to Step 3 | |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 10 | |
Does the test lamp turn ON and OFF with each command? | Go to Step 8 | Go to Step 5 | |
Does the test lamp remain illuminated with each command? | Go to Step 7 | Go to Step 6 | |
Test the control circuit of the after blow relay for a short to voltage or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 9 | |
7 | Test the control circuit of the after blow relay for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 9 |
8 | Inspect for poor connections at the after blow relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 11 |
9 | Inspect for poor connections at the harness connector of the body control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
10 | Repair the battery positive voltage circuit of the after blow relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 13 | -- |
11 | Replace the after blow relay. Did you complete the replacement? | Go to Step 13 | -- |
Important: Perform the setup procedure for the body control module . Replace the body control module. Refer to Body Control Module Replacement in Body Control System. Did you complete the replacement? | Go to Step 13 | -- | |
13 |
Does the DTC reset? | Go to Step 2 | System OK |