Table 1: | HO2S Voltages |
The wide band heated oxygen sensor (HO2S) measures the amount of oxygen in the exhaust system and provides more information than the switching style HO2S. The wide band sensor consists of an oxygen sensing cell, an oxygen pumping cell, and a heater. The exhaust gas sample passes through a diffusion gap between the sensing cell and the pumping cell. The powertrain control module (PCM) supplies a voltage to the HO2S and uses this voltage as a reference to the amount of oxygen in the exhaust system. An electronic circuit within the PCM controls the pump current through the oxygen pumping cell in order to maintain a constant voltage in the oxygen sensing cell. The PCM monitors the voltage variation in the sensing cell and attempts to keep the voltage constant by increasing or decreasing the amount of current flow, or oxygen ion flow, to the pumping cell. By measuring the amount of current required to maintain the voltage in the sensing cell, the PCM can determine the concentration of oxygen in the exhaust. The HO2S voltage is displayed as a lambda value. A lambda value of 1 is equal to a stoichiometric air fuel ratio of 14.7:1. Under normal operating conditions, the lambda value will remain around 1. When the fuel system is lean, the oxygen level will be high and the lambda signal will be high or more than 1. When the fuel system is rich, the oxygen level will be low, and the lambda signal will be low or less than 1. The PCM uses this information to maintain the correct air/fuel ratio. If the PCM detects that the sensing cell voltage fluctuates above and below predetermined values for a fixed amount of time this DTC sets.
This diagnostic procedure supports the following DTCs.
• | DTC P2243 HO2S Reference Voltage Circuit Bank 1 Sensor 1 |
• | DTC P2247 HO2S Reference Voltage Circuit Bank 2 Sensor 1 |
• | The engine is operating. |
• | The HO2S heater is commanded ON. |
• | DTC P2243 and DTC P2247 both run continuously once the above conditions have been met. |
• | The HO2S sensing cell voltage fluctuates between 4.8 volts or more and 3.4 volts or less. |
• | The voltage oscillations occur 50 consecutive times or more. |
• | The condition exists for 7 seconds. |
• | The PCM illuminates the malfunction indicator lamp (MIL) when the diagnostic runs and fails. |
• | The PCM records the operating conditions at the time the diagnostic fails. The PCM stores this information in the Freeze Frame and/or Failure Records. |
• | The PCM turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A last test failed, or current DTC, clears when the diagnostic runs and does not fail. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Use a scan tool in order to clear the MIL and the DTC. |
• | Use the J-35616 Connector Test Adapter Kit for any test that requires probing the PCM harness connector or a component harness connector. |
• | The Loop Status for the respective bank will default to Open when the DTC is current. |
• | The wide band sensors do not toggle or switch like a switching HO2S. The HO2S signals will be relatively stable for an idling engine. |
• | For an intermittent condition, refer to Intermittent Conditions . |
• | The following table illustrates the typical voltages for the HO2S circuits: |
| |||||
---|---|---|---|---|---|
HO2S Circuit | Voltage | ||||
Heater Control | Less than 0.5 V | ||||
Heater Supply Voltage | B+ | ||||
Reference Voltage | 3.3-3.8 V | ||||
Low Reference | 5.9-6.4 V | ||||
Pump Current | 4.8-5.3 V | ||||
Input Pump Current | 3.3-3.8 V |
The numbers below refer to the step numbers on the diagnostic table.
This step determines wether a condition currently exists. If the Lambda value fluctuates near 1.00 and Loop Status is Closed, the HO2S is operating correctly.
This step tests for a condition in the reference voltage circuit. Test for an open or a high resistance if the voltage measures less than 0.1 volts.
This step tests for a condition in the HO2S low reference circuit. If the voltage measured on the HO2S heater control circuit is more than 1.0 volt, test for a wire to wire short between the low reference circuit and the heater control circuit.
Inspect the HO2S connector for water intrusion, corrosion, and bent or damaged terminals.
Inspect the PCM connectors for water intrusion, corrosion, and bent or damaged terminals.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: Engine Controls Schematics Connector End View Reference: Powertrain Control Module Connector End Views or Engine Controls Connector End Views | ||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |
Important: DTC P2243 is for bank 1 sensor 1 - Rear and DTC P2247 is for bank 2 sensor 1 - Front.
Does the scan tool display Closed Loop? | -- | Go to Step 3 | Go to Step 4 | |
3 |
Did the DTC fail this ignition? | -- | Go to Step 4 | Go to Diagnostic Aids |
Is the voltage more than the specified value? | 1.0 V | Go to Step 5 | Go to Step 6 | |
Measure the voltage between the HO2S heater control circuit and a good ground with a DMM. Is the voltage more than the specified value? | 1.0 V | Go to Step 7 | Go to Step 8 | |
6 | Test the reference voltage circuit of the HO2S for an open, or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 9 |
7 | Test the low reference circuit of the HO2S for a short to the HO2S heater control circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 9 |
Test for shorted terminals and for poor connections at the HO2S sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 10 | |
Test for shorted terminals and for poor connections at the PCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 11 | |
10 | Replace the HO2S sensor. Refer to Heated Oxygen Sensor Replacement - Bank 1 Sensor 1 or Heated Oxygen Sensor Replacement - Bank 2 Sensor 1 . Did you complete the replacement? | -- | Go to Step 12 | -- |
11 | Replace the PCM. Refer to Powertrain Control Module Replacement . Did you complete the replacement? | -- | Go to Step 12 | -- |
12 |
Did the DTC fail this ignition? | -- | Go to Step 2 | Go to Step 13 |
13 | Observe the Capture Info with a scan tool. Are there any DTCs that have not been diagnosed? | -- | System OK |