Instrument Panel Compartment Door Lock Cylinder Replacement SKY
Removal Procedure
- Remove the instrument panel (I/P) compartment latch. Refer to
Instrument Panel Compartment Door Latch Replacement.
- Position the I/P compartment latch fork bolt in the up position.
- Insert the key into the I/P compartment lock cylinder.
- Rotate the I/P compartment lock cylinder clockwise to the 3 o'clock position with the key.
- With the key in position, apply a light load and depress the retainer tumbler through the poke hole at the right hand side of the I/P compartment latch.
- Rotate the key until the I/P compartment lock cylinder rotates to about the 5 o'clock position.
This will line up the notch at the rear of the I/P compartment lock cylinder with the tab in the I/P compartment
latch housing.
- Remove the I/P compartment lock cylinder from the I/P compartment latch by pulling on the key.
Installation Procedure
- Position the I/P compartment latch fork bolt in the up position.
- Grasp the I/P compartment lock cylinder. Depress the rear-most, light-colored tumbler that is flush with the I/P compartment lock cylinder surface.
- Insert the key.
All the tumblers will now stay depressed.
- Insert the I/P compartment lock cylinder, with the key inserted, into the I/P compartment latch housing. Ensure that the front projection pin is at the appropriate 8 o'clock position.
The I/P compartment lock cylinder will drop
into place.
- Rotate the key counterclockwise until the key stops.
- Remove the key, the tumblers will now release.
The I/P compartment lock cylinder is now locked into the I/P compartment latch housing.
- Install the I/P compartment latch. Refer to
Instrument Panel Compartment Door Latch Replacement.
Instrument Panel Compartment Door Lock Cylinder Replacement Solstice
Removal Procedure
- Remove the instrument panel (I/P) compartment latch. Refer to
Instrument Panel Compartment Door Latch Replacement .
- Position the I/P compartment latch fork bolt in the up position.
- Insert the key into the I/P compartment lock cylinder.
- Rotate the I/P compartment lock cylinder clockwise to the 3 o'clock position with the key.
- With the key in position, apply a light load and depress the retainer tumbler through the poke hole at the right hand side of the I/P compartment latch.
- Rotate the key until the I/P compartment lock cylinder rotates to about the 5 o'clock position.
This will line up the notch at the rear of the I/P compartment lock cylinder with the tab in the I/P compartment
latch housing.
- Remove the I/P compartment lock cylinder from the I/P compartment latch by pulling on the key.
Installation Procedure
- Position the I/P compartment latch fork bolt in the up position.
- Grasp the I/P compartment lock cylinder. Depress the rear-most, light-colored tumbler that is flush with the I/P compartment lock cylinder surface.
- Insert the key.
All the tumblers will now stay depressed.
- Insert the I/P compartment lock cylinder, with the key inserted, into the I/P compartment latch housing. Ensure that the front projection pin is at the appropriate 8 o'clock position.
The I/P compartment lock cylinder will drop
into place.
- Rotate the key counterclockwise until the key stops.
- Remove the key, the tumblers will now release.
The I/P compartment lock cylinder is now locked into the I/P compartment latch housing.
- Install the I/P compartment latch. Refer to
Instrument Panel Compartment Door Latch Replacement .