Subject: | EI07084 -- Power Sliding Door Increased Effort While Opening (Engineering Information) |
Models: | 2007 Buick Terraza |
2007 Chevrolet Uplander |
2007 Saturn Relay |
with Power Sliding Door-Right (RPO E58) and/or Power Sliding Door-Left (RPO E59) |
Vehicles Located in Michigan, Georgia or Florida |
Attention: | Proceed with this bulletin ONLY if the customer has commented about this concern AND the EI number is listed in GMVIS. If the customer has not commented about this condition or the EI does not show in GMVIS, disregard the bulletin and proceed with diagnostics found in published service information. THIS IS NOT A RECALL -- refer to Service Bulletin 04-00-89-053A for more detail on the use of Engineering Information bulletins. |
Important: If the customer did not bring their vehicle in for this issue, do not proceed with this bulletin.
Some customers may comment on increased effort when opening the power sliding door.
GM Engineering is attempting to determine the root cause of this condition. GM has a need to obtain technical information from the dealer technician during diagnosis and PRIOR to repair. As a result, this information will be used by engineering to help root-cause the customer's concern and develop/validate a field fix.
Important: This bulletin applies to vehicles located in Michigan, Georgia and Florida only. All others should continue to diagnose and repair according to information found in SI.
During diagnosis of the customer's concern, document the following information on the repair order:
• | Are there any unusual noises? If so describe. |
• | Is the door slow to open? |
• | Does the door close completely? |
• | Describe overall performance of power door operation compared to the like vehicle. |
• | Are the rollers loose or off track? |
• | Is the cable bound or does it have too much slack? |
• | Are any of the components damaged or broken? |
• | MICHIGAN: Leon Brandow -- 248-318-4580 |
• | GEORGIA / FLORIDA: Dana Mann -- 404-379-2948 |
Labor Operation | Description | Labor Time |
---|---|---|
B9820* | Power Sliding Door -- Engineering Information | 0.3 hr |
Add | To adjust cable | 0.7 hr |
Add | To replace roller and/or bracket | 0.3 hr |
Add | To replace motor, clutch assembly | 1.4 hrs |
Add | To replace sliding door locating pin | 0.2 hr |
*This labor operation number is for bulletin use only. The number will not be published in the Labor Time Guide. |