Removal Procedure
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
- Using a back-up wrench to support service port base, use a second wrench
to remove the valve assembly.
Installation Procedure
- Lubricate the valve assembly O-ring with mineral oil.
- Thread the valve assembly into the service port base.
Tighten
Tighten the valve to 12 N·m (106 lb in).
Important: To prevent loss of refrigerant charge, make sure to install and tighten cap.
Replace cap if seal is missing or damaged.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Using the J 39400-A
leak test the fittings of the component.