Removal Procedure
- Disconnect the AIR pump solenoid harness connector.
- Remove the vacuum hoses.
- Remove the bolts.
- Remove the AIR pump solenoid.
Installation Procedure
- Install the AIR pump solenoid.
Notice: Refer to Fastener Notice in the Preface section.
- Install the AIR pump solenoid bolt.
Tighten
Tighten the AIR pump solenoid bolt to 10 N·m (89 lb in).
- Install the vacuum hoses.
- Connect the AIR pump solenoid harness connector. Push in the connector
until a click is heard and pull back to confirm a positive engagement.