Diagnostic Instructions
DTC Descriptor
DTC P0520 : Engine Oil Pressure (EOP) Sensor Circuit
Diagnostic Fault Information
Circuit
| Short to Ground
| Open/High Resistance
| Short to Voltage
| Signal Performance
|
Engine Oil Pressure Sensor Signal Circuit
| 1
| P0520
| P0520
| --
|
Engine Oil Pressure Sensor Ground Circuit
| --
| P0520
| --
| --
|
1. Engine Oil Pressure Indicator Always On
|
Circuit/System Description
The engine oil pressure (EOP) switch is a normally closed switch that opens with the proper oil pressure. With the ignition switch turned ON and the engine not running, the engine control module (ECM)/powertrain control module (PCM) should detect a low
signal voltage input. With the engine running, the pressure switch opens, and the ECM/PCM should detect a high signal voltage input. The ECM/PCM tests the state of the EOP circuit with the ignition switch turned ON, and the engine turned OFF. When the oil pressure
is low, the ECM/PCM sends a GMLAN serial data message to the body control module (BCM) requesting the EOP indicator turned ON. The instrument panel cluster (IPC) illuminates the EOP indicator when the IPC receives a serial data message from the BCM requesting
the EOP indicator turned ON.
Conditions for Running the DTC
The ignition is ON, with the engine ON.
Conditions for Setting the DTC
• | The ECM/PCM detects that the EOP sensor signal circuit is pulled high. |
• | The above condition is present for greater than 10 seconds. |
Action Taken When the DTC Sets
• | The ECM/PCM records the operating conditions at the time the diagnostic test fails. The ECM/PCM displays this information in the Failure Records on the scan tool. |
• | The instrument panel cluster (IPC) illuminates the engine oil pressure indicator. |
Conditions for Clearing the DTC
• | The DTC becomes history when the conditions for setting the DTC are no longer present. |
• | The history DTC clears after 40 malfunction-free warm-up cycles. |
• | The ECM/PCM receives a clear code command from the scan tool. |
Reference Information
Schematic Reference
Connector End View Reference
Electrical Information Reference
Scan Tool Reference
Scan Tool Data List
Circuit/System Testing
Important: Do not turn the key to the crank position or engage the starter at any time during diagnosis.
- Ignition OFF, disconnect the engine oil pressure (EOP) switch connector.
- Ignition OFF, test for less than 1 ohm of resistance between the ground circuit and ground.
⇒ | If greater than 1 ohm, test the ground circuit for an open/high resistance. |
- Ignition ON, install a 3-amp fused jumper wire between the signal circuit of the EOP switch and ground. Verify the scan tool Engine Oil Pressure Switch parameter is Low.
⇒ | If not Low, test the signal circuit of the EOP switch for a short to voltage or an open/high resistance. If circuit test normal, replace the ECM/PCM. |
- If all circuits test normal, replace the engine oil pressure switch.
Repair Instructions
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.