• | The battery positive voltage circuit of the power window switch is not protected by a fuse. Instead, the power window switch is designed to open internally should a circuit overload occur. A mirror motor control circuit shorted to ground could cause this type of failure. |
• | If both power mirrors are inoperative on one or more axis, the most probable cause is a power mirror switch failure. However the fault could be an open circuit on two or more of the power mirror control circuits. |
• | The power mirror assembly is equipped with a pigtail harness and is not serviceable. If an internal open or short is detected in the power mirror assembly, replace the power mirror assembly. |
The numbers below refer to the step numbers on the diagnostic table.
This step tests the integrity of both the mirror control circuits and the power mirror switch. If both power mirrors are inoperative on one or more axis, begin testing by disconnecting one of the power mirrors, if an open circuit is detected and repaired for that power mirror, repeat step 6 for the other power mirror.
This step tests the integrity of the battery positive voltage circuit.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Outside Rearview Mirror Schematics Connector End View Reference: Mirror Connector End Views | |||
1 | Did you review the Outside Mirror Description and Operation? | Go to Step 2 | |
2 |
Do both power mirrors operate properly? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Are both the left and right power mirrors completely inoperative? | Go to Step 4 | Go to Step 6 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 7 |
5 | Connect a test lamp between the battery positive voltage circuit of the power mirror switch harness connector and the ground circuit of the power mirror switch harness connector. Does the test lamp illuminate? | Go to Step 9 | Go to Step 15 |
Does the test lamp illuminate in both directions? | Go to Step 12 | Go to Step 8 | |
Test the battery positive voltage circuit of the power mirror switch for a short to ground or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 18 | Go to Step 9 | |
8 | Test the mirror motor control circuits for an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 18 | Go to Step 9 |
9 |
Did the test lamp illuminate at any of the power mirror motor control circuits? | Go to Step 13 | Go to Step 10 |
10 | Probe each of the power mirror motor control circuits of the power mirror switch harness connector with a test lamp that is connected to a good ground. Did the test lamp illuminate at any of the power mirror motor control circuits? | Go to Step 14 | Go to Step 11 |
11 | Inspect for poor connections at the harness connector of the power mirror switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 18 | Go to Step 16 |
12 | Inspect for poor connections at the harness connector of the power mirror. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 18 | Go to Step 17 |
13 | Repair the short to ground in the power mirror motor control circuit. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair? | Go to Step 18 | -- |
14 | Repair the short to battery positive voltage in the power mirror motor control circuit. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair? | Go to Step 18 | -- |
15 | Repair the open in the power mirror switch ground circuit. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair? | Go to Step 18 | -- |
16 | Replace the power mirror switch. Refer to Upper Extension Trim Panel Replacement . Did you complete the replacement? | Go to Step 18 | -- |
17 | Replace the power mirror. Refer to Outside Rearview Mirror Replacement . Did you complete the replacement? | Go to Step 18 | -- |
18 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |