The electrically erasable read only memory (EEPROM) check sum error detection is handled inside the control module. No external circuits are involved.
The module runs the program to detect an EEPROM checksum error after each wake-up. The only requirements are battery positive voltage and ground. This program runs even if the voltage is out of the valid operating range.
The module retains an inverse copy of the digital value stored in certain blocks of memory in the EEPROM. The module then reads the information from those certain blocks and adds the stored inverse value to the current value. If they do not equal 0, the module sets the DTC.
The module reverts to base operation values programed for those blocks of data that have failed the check sum test. The blocks of data that have not failed the check sum test are not affected.
• | A current DTC clears when the malfunction is no longer present. |
• | A history DTC clears when the module ignition cycle counter reaches the reset threshold, without a repeat of the malfunction. |
• | This DTC may be retrieved as a history DTC without affecting the operation of the module. If the DTC is retrieved as a history DTC and not retrieved as a current DTC, do not replace the module. |
• | If this DTC is retrieved as both a current and history DTC, replace the module. |
Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Diagnostic System Check for the system exhibiting the symptom? | Go to Step 2 | Go to Control Module References for the applicable Diagnostic System Check |
2 |
Is the DTC retrieved as a current DTC? | Go to Step 3 | Go to Diagnostic Aids |
3 |
Important: Perform the programming or setup procedure for the module if required. Replace the control module setting the DTC as current. Refer to Control Module References . Did you complete the replacement? | Go to Step 4 | -- |
4 |
Does the DTC reset? | Go to Step 2 | System OK |