Removal Procedure
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
- Remove the block connector, refrigerant lines, from expansion valve.
2.2. | Disconnect the refrigerant lines. |
Important: If installation is postponed, close off lines and connections.
- Remove the thermostatically controlled expansion valve (TXV) (1).
Insert the bolt, block connector refrigerant line, in expansion valve (2) and remove the expansion valve.
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Install the TXV.
• | Use new sealing rings, before installation moisten only green colored sealing rings with mineral oil and insert. |
• | Install the service threaded rods (2) into retaining clip (1) to guide expansion valve. |
• | Push the expansion valve onto service threaded rods until the refrigerant lines lie in the expansion valve. |
• | Replace threaded rods in succession with fixing bolts. |
Tighten
Tighten the expansion valve bolts to 6 N·m (53 lb in).
- Install the block connector.
- Use the new sealing rings, before installation moisten only green colored sealing rings with mineral oil and insert.
Tighten
Tighten the block connector bolt to 7 N·m (62 lb in).
- Recharge the air conditioning system. Refer to
Refrigerant Recovery and Recharging
.