Caution: The high intensity discharge system produces high voltage and current. In order to reduce the risk of severe shocks and burns, the battery negative cable must be disconnected any time service work is being performed on or around the high intensity discharge system.
Caution: The high intensity discharge system produces high voltage and current.
To reduce the risk of severe shocks and burns:
• Never open the high intensity discharge system ballast or the
arc tube assembly starter. • Never probe between the high intensity discharge system ballast
output connector and the arc tube assembly.
Caution: Refer to Halogen Bulb Caution in the Preface section.
Important: Warning, high voltage. Do not touch components in the xenon dipped beam when the dipped beam is switched on. Ignition and light switch OFF.
Remove the 3 bolts (1).
To unlock, turn in the direction of the arrow.
• | Disconnect the wiring harness plug. |
• | Remove the igniter. |
Compress the fixing bracket (1) to release.
Important: Ensure correct installation position.
• | Insert the xenon lamp. |
• | Lock the fixing bracket. |
Important: The arrow on the sticker (igniter) must be at the bottom on installation.
To lock, turn opposite the direction of the arrow.
• | Insert the igniter. |
• | Connect the wiring harness plug. |
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the 3 bolts to 2.5 N·m (22 lb in).