Caution: Refer to Battery Disconnect Caution in the Preface section.
• | Remove the ground connection from the ground terminal. |
• | Loosen the nut. |
Remove the nut.
Remove the 2 nuts.
• | Disconnect the wiring harness plug of the catalytic converter control oxygen sensor. |
• | Disconnect the wiring harness plug (1) from the bracket. |
• | Remove the 2 bolts (3). |
Remove the 2 bolts (1, 2).
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the 2 bolts to 25 N·m (18 lb ft).
Tighten
Tighten the 2 bolts to 8 N·m (70 lb in).
• | Install the wiring harness plug into the bracket. |
• | Connect the wiring harness plug for the catalytic converter control oxygen sensor. |
Tighten
Tighten the 2 nuts to 12.5 N·m (110 lb in).
Tighten
Tighten the nut to 12.5 N·m (110 lb in).
Install the ground connection to the ground terminal.
Tighten
Tighten the nut to 12.5 N·m (110 lb in).