Diagnostic Instructions
Circuit/System Description
Ignition voltage is supplied to the malfunction indicator lamp (MIL). The engine control module (ECM) turns the MIL ON by grounding the MIL control circuit.
Reference Information
Schematic Reference
Connector End View Reference
Component Connector End Views
Electrical Information Reference
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Verification
Ignition ON, the MIL should turn ON and OFF when commanded with a scan tool.
Circuit/System Testing
- Ignition ON, verify that the instrument panel cluster (IPC) warning indicators are illuminated.
⇒ | If the IPC warning indicators are not illuminated, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, replace the IPC. |
- Ignition OFF, disconnect connector X2 at the ECM.
- Ignition ON, verify that the MIL is not illuminated.
⇒ | If the MIL is illuminated inspect the MIL control circuit for a short to ground. If the circuit tests normal, replace the IPC. |
- Ignition ON, verify that the MIL illuminates with a 3A fused jumper between the MIL control circuit X2-1 and ground.
⇒ | If the MIL does not illuminate test the MIL control circuit for a short to voltage or an open/high resistance. If the circuit tests normal replace the ECM. |
Repair Instructions
Perform the
Diagnostic Repair Verification after completing the diagnostic procedure.