The engine control module (ECM) uses the generator turn on signal circuit to control the load of the generator on the engine. A high side driver in the ECM applies a voltage to the voltage regulator. This signals the voltage regulator to turn the field circuit ON and OFF. When the ECM turns ON the high side driver, the voltage regulator turns ON the field circuit. When the ECM turns OFF the high side driver, the voltage regulator turns OFF the field circuit.
The ECM monitors the state of the generator turn on signal circuit. With the engine running, the ECM should detect a high generator turn on signal circuit.
This diagnostic procedure supports the following DTC:
DTC P2500 Generator L-Terminal Circuit Low Voltage
• | No generator, crankshaft position (CKP) sensors, or camshaft position (CMP) sensor DTCs are set. |
• | The engine is running. |
• | The generator has not been commanded OFF by the ECM or scan tool. |
The ECM detects a low signal voltage on the generator turn on signal circuit for at least 15 seconds.
• | The ECM will not illuminate the malfunction indicator lamp (MIL). |
• | The ECM will store the conditions present when the DTC set as Fail Records data only. |
• | The ECM will send a class 2 serial data message to the instrument panel cluster (IPC) and driver information center (DIC) to illuminate the charge indicator or display a charging message. |
• | The conditions for setting DTC P2500 are not present. |
• | The DTC can be cleared by using the scan tool Clear DTC Information function. |
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: Starting and Charging Schematics Connector End View Reference: Engine Controls Connector End Views for the 2.0L (LNF) engine or Engine Controls Connector End Views for the 2.4L (LE5) engine | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |
2 |
Does the scan tool indicate that the GEN - F Terminal parameter is within the specified range? | 5-100% | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Is the voltage within the specified range? | 4.5-5.5 V | Go to Step 5 | Go to Step 4 |
4 | Test the generator turn on signal circuit for a short to ground or open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 6 |
5 | Inspect for poor connections at the harness connector of the generator. Refer to Connector Repairs . Did you find and correct the condition? | -- | Go to Step 8 | Go to Charging System Test |
6 | Inspect for poor connections at the harness connector of the engine control module (ECM). Refer to Connector Repairs . Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 7 |
7 | Replace the ECM. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 8 | -- |
8 |
Does the scan tool indicate that DTC P2500 failed? | -- | Go to Step 2 | System OK |
The engine control module (ECM) uses the generator turn on signal circuit to control the load of the generator on the engine. A high side driver in the ECM applies a voltage to the voltage regulator. This signals the voltage regulator to turn the field circuit ON and OFF. When the ECM turns ON the high side driver, the voltage regulator turns ON the field circuit. When the ECM turns OFF the high side driver, the voltage regulator turns OFF the field circuit.
The ECM monitors the state of the generator turn on signal circuit. With the engine running, the ECM should detect a high generator turn on signal circuit.
This diagnostic procedure supports the following DTC:
DTC P2500 Generator L-Terminal Circuit Low Voltage
• | No generator, crankshaft position (CKP) sensors, or camshaft position (CMP) sensor DTCs are set. |
• | The engine is running. |
• | The generator has not been commanded OFF by the ECM or scan tool. |
The ECM detects a low signal voltage on the generator turn on signal circuit for at least 15 seconds.
• | The ECM will not illuminate the malfunction indicator lamp (MIL). |
• | The ECM will store the conditions present when the DTC set as Fail Records data only. |
• | The ECM will send a class 2 serial data message to the instrument panel cluster (IPC) and driver information center (DIC) to illuminate the charge indicator or display a charging message. |
• | The conditions for setting DTC P2500 are not present. |
• | The DTC can be cleared by using the scan tool Clear DTC Information function. |
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: Starting and Charging Schematics Connector End View Reference: Engine Controls Connector End Views | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |
2 |
Does the scan tool indicate that the GEN - F Terminal parameter is within the specified range? | 5-100% | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Is the voltage within the specified range? | 4.5-5.5 V | Go to Step 5 | Go to Step 4 |
4 | Test the generator turn on signal circuit for a short to ground or open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 6 |
5 | Inspect for poor connections at the harness connector of the generator. Refer to Connector Repairs . Did you find and correct the condition? | -- | Go to Step 8 | Go to Charging System Test |
6 | Inspect for poor connections at the harness connector of the engine control module (ECM). Refer to Connector Repairs . Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 7 |
7 | Replace the ECM. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 8 | -- |
8 |
Does the scan tool indicate that DTC P2500 failed? | -- | Go to Step 2 | System OK |