• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
ECT Sensor Signal | P0117 | P0118 | P0118 | P0118 | P0116, P0128 |
Low Reference | -- | P0118 | P0118 | P0118 | P0128 |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Engine Running Parameter Normal Range: -39 to +120°C (-38 to +248°F) | |||
ECT Sensor Signal | 150°C (302°F) | -40°C (-40°F) | -40°C (-40°F) |
Low Reference | -- | -40°C (-40°F) | -40°C (-40°F) |
The engine coolant temperature (ECT) sensor is a variable resistor that measures the temperature of the engine coolant. The engine control module (ECM) supplies 5 volts to the ECT sensor signal circuit and supplies a ground to the low reference circuit.
The purpose of this diagnostic is to analyze the performance of the thermostat, by using the ECT sensor to determine if the engine coolant will increase at the correct rate, and also meet the calibrated target temperatures under various operating conditions.
The ECM uses the start-up ECT and the start-up intake air temperature (IAT) to begin the diagnostic calculation. The air flow into the engine is accumulated , and vehicle speed, distance, and engine run time are also factored in to determine if the ECT does increase normally and reach the calibrated target temperatures.
• | DTCs P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0121, P0122, P0123, P0502, P0503 are not set. |
• | The start-up IAT is between -7 to +55°C (+19 to +131°F). |
• | The start-up ECT is less than 50°C (122°F) when the start-up IAT is less than 10°C (50°F). |
OR |
• | The start-up ECT is less than 75°C (167°F) when the start-up IAT is greater than 10°C (50°F). |
• | The engine run time is between 30 seconds and 30 minutes. |
• | The vehicle has traveled greater than 0.8 kilometers (0.5 miles) at greater than 8 km/h (5 mph). |
• | The mass air flow (MAF) average is greater than 1 g/s. |
• | This DTC runs once per ignition cycle within the enabling conditions. |
• | The ECM detects that the minimum ECT of 55°C (131°F) has not been met with a start-up IAT of less than 10°C (50°F). |
OR |
• | The ECM detects that the minimum ECT of 80°C (176°F) has not been met with a start-up IAT of greater than 10°C (50°F). |
DTC P0128 is a Type B DTC.
DTC P0128 is a Type B DTC.
• | DTC P0128 occurring with insufficient vehicle interior heating is an indication of improper thermostat operation. |
• | Inspect the ECT sensor terminals and the ECT harness connector for corrosion. This condition results in a greater voltage on the ECT sensor signal circuit, which is interpreted by the ECM as a colder ECT. |
• | This diagnostic runs in a specific range. Measure and record the resistance of the ECT sensor at various ambient temperatures between -7 to +80°C (+19 to +176°F), then compare those measurements to the Temperature vs Resistance table. Refer to Temperature Versus Resistance . |
• | A slight to moderate resistance in the ECT sensor signal circuit or low reference circuit will affect this diagnostic. This condition results in a greater voltage on the ECT sensor signal circuit, which is interpreted by the ECM as a colder ECT. |
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Caution: Under pressure, the temperature of the solution in the radiator can be considerably higher, without boiling. Removing the radiator cap while the engine is hot (pressure is high), will cause the solution to boil instantaneously, with explosive force. The solution will spew out over the engine, fenders, and the person removing the cap. Serious bodily injury may result. Flammable antifreeze, such as alcohol, is not recommended for use at any time. Flammable antifreeze could cause a serious fire.
Important: A critical analysis of the operation of the thermostat is necessary to properly diagnose this DTC.
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the signal circuit terminal 2 for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
Measure and record the resistance of the ECT sensor at various ambient temperatures, then compare those measurements to the Temperature vs Resistance table. Refer to Temperature Versus Resistance .
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |