The powertrain control module (PCM) monitors the high side refrigerant pressure through a air conditioning (A/C) refrigerant pressure sensor. When the pressure is high the signal voltage is high. When the pressure is low the signal voltage is low. When pressure is high the PCM commands the cooling fans ON. When pressure is too high or too low the PCM will not allow the A/C compressor clutch to engage.
This diagnostic procedure supports the following DTC:
DTC P0530 Air Conditioning Refrigerant Pressure Sensor Circuit
The PCM detects the signal circuit is less than 5 counts (0.09 volts) or more than 250 counts (4.90 volts).
The condition exists for 20 seconds.
• | The PCM will not illuminate the malfunction indicator lamp (MIL). |
• | The PCM stores the failure records. |
• | The A/C compressor clutch is disabled. |
• | The DTC will become history if the PCM no longer detects a failure. |
• | The history DTC will clear after 40 consecutive warm-up cycles have occurred without a malfunction. |
• | The DTC can be cleared with a scan tool. |
The numbers below refer to the step numbers on the diagnostic table.
Tests for the proper operation of the circuit in the low voltage range.
Tests for the proper operation of the circuit in the high voltage range. If the fuse in the jumper opens when you perform this test, the signal circuit is shorted to ground.
Tests for a short to voltage in the 5-volt reference circuit.
Tests for a high resistance or an open in the low reference circuit.
Perform the programming procedure for the PCM.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |
2 |
Important: The ambient air temperature must be above 3°C (38°F).
Does the A/C compressor operate? | -- | Go to Step 3 | |
3 |
Does the scan tool indicate that the A/C High Side Pressure parameter is within the specified range? | 0.09-4.90 V | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 4 |
Does the scan tool indicate that the A/C High Side Pressure parameter is less than the specified value? | 0.09 V | Go to Step 5 | Go to Step 11 | |
Does the scan tool indicate that the A/C High Side Pressure parameter is more than the specified value? | 4.90 V | Go to Step 6 | Go to Step 9 | |
Does the voltage measure less than the specified value? | 5.1 V | Go to Step 7 | Go to Step 8 | |
Does the resistance measure less than the specified value? | 5 ohms | Go to Step 13 | Go to Step 12 | |
8 | Test the 5-volt reference circuit of the A/C refrigerant pressure sensor for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 14 |
9 | Test the 5-volt reference circuit of the A/C refrigerant pressure sensor for a short to ground, a high resistance, or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 10 |
10 | Test the signal circuit of the A/C refrigerant pressure sensor for a short to ground, a high resistance, or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 14 |
11 | Test the signal circuit of the A/C refrigerant pressure sensor for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 14 |
12 |
Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 14 |
13 | Inspect for poor connections at the harness connector of the A/C refrigerant pressure sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 15 |
14 | Inspect for poor connections at the harness connector of the PCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 17 | Go to Step 16 |
15 | Replace the A/C refrigerant pressure sensor. Refer to Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement . Did you complete the replacement? | -- | Go to Step 17 | -- |
Replace the PCM. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 17 | -- | |
17 |
Does the DTC reset? | -- | Go to Step 2 | System OK |