Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Rotate the drive belt tensioner counter
clockwise.
- Remove the generator. Refer to
Generator Replacement
.
- Remove the drive belt tensioner bolt.
- Remove the drive belt tensioner.
- Remove the drive belt idler pulley bolt.
- Remove the drive belt idler pulley.
- Remove the generator bracket bolts.
- Remove the generator bracket.
Installation Procedure
- Install the generator bracket.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator bracket bolts.
Tighten
Tighten the bolts in sequence to 50 N·m (37 lb ft).
- Install the drive belt tensioner.
- Install the drive belt tensioner bolt.
Tighten
Tighten the bolt to 50 N·m (37 lb ft).
- Install the drive belt idler pulley.
- Install the drive belt idler pulley bolt.
Tighten
Tighten the bolt to 50 N·m (37 lb ft).
- Install the generator. Refer to
Generator Replacement
.
- Rotate the drive belt tensioner counter clockwise.
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.