Removal Procedure
- Remove the intake manifold cover. Refer
to
Intake Manifold Cover Replacement.
- Disconnect the intake camshaft position (CMP) sensor electrical connector
(1).
- Remove the CMP sensor bolt.
- Remove the CMP sensor.
Installation Procedure
Important: Inspect the CMP sensor for damage, replace
as necessary.
- Lubricate the CMP sensor O-ring seal with clean engine oil.
Notice: Refer to Fastener Notice in the Preface section.
- Install the CMP sensor.
- Install the CMP sensor bolt.
Tighten
Tighten the bolt to 10 N·m (89 lb in).
- Connect the intake CMP sensor electrical
connector (1).
- Install the intake manifold cover. Refer to
Intake Manifold Cover Replacement.