S15 and S16 are part of the Folding Top Open/Close switch. The Folding Top Control (FTC) Module uses the Folding Top Open/Close switch to determine the appropriate action of the top. S15 is closed and pulls the signal circuit low when holding the Folding Top Open/Close switch in the open position. S16 is closed and pulls the signal circuit low when holding the Folding Top Open/Close switch in the close position.
The Folding Top Control (FTC) module is operational.
A short to ground is detected on the signal circuit of S15 or S16.
A short to ground is detected on the signal circuits of S15 and S16.
The top is disabled.
The fault is no longer present and the top completes one cycle.
Power Roof Systems Connector End Views
Power Folding Top Description and Operation
⇒ | If scan tool indicates Opening, test the signal circuit of S15 for a short to ground. If circuit OK, replace FTC Module. |
⇒ | If scan tool indicates Closing, test the signal circuit of S16 for a short to ground. If circuit OK, replace FTC Module. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.