DTC Descriptor

DTC P1668 : Generator L-Terminal Control Circuit

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Generator L- Terminal Circuit

P1668

P1668

P1668

Circuit/System Description

The engine control module (ECM) uses the generator turn ON signal circuit to control the load of the generator on the engine. A high side driver in the ECM applies a voltage to the voltage regulator. This signals the voltage regulator to turn the field circuit ON and OFF. The ECM monitors the state of the generator turn ON signal circuit. The ECM should detect low voltage on generator turn ON signal circuit when the ignition is ON and the engine is OFF, or when the charging system malfunctions. With the engine running, the ECM should detect high voltage on the generator turn ON signal circuit. The ECM performs tests to determine the status of the generator turn ON signal circuit.

Conditions for Running the DTC

The engine is running.

Conditions for Setting the DTC

With the engine running the ECM detects a low voltage on the generator turn ON signal circuit for at least 15 seconds.

Action Taken When the DTC Sets

    • The ECM will command the charge indicator and or warning message to be illuminated on the instrument panel cluster (IPC) and the driver information center (DIC), if equipped.
    • The ECM will not illuminate the malfunction indicator lamp (MIL).
    • The ECM will store conditions, which were present when the DTC set as Fail Records data only.

Conditions for Clearing the DTC

The history DTC will clear after 40 consecutive warm-up cycles have occurred without a malfunction.

Reference Information

Schematic Reference

Starting and Charging Schematics

Connector End View Reference

Engine Electrical Connector End Views

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Circuit/System Testing

  1. With ignition ON, and the engine OFF, disconnect the generator harness and measure the voltage of the generator turn ON signal circuit, should read near 0 volts.
  2. If greater than 0 volts, test the generator turn ON signal circuit for a short to voltage or replace the ECM.
  3. With ignition ON, and the engine running, the voltage of the generator turn ON signal circuit, should read over 3.5 volts.
  4. If no voltage is measured, test the generator turn ON signal circuit for a short to ground, an open or a high resistance or replace the ECM.
  5. Refer to Charging System Test .

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

Control Module References for ECM replacement, setup, and programming