Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics | |||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 | Verify that the IP compartment door closes properly. Does the IP compartment door close properly? | Go to Step 4 | Go to Step 3 |
3 | Adjust or repair the IP compartment door. Refer to Instrument Panel Compartment Door Lock Striker Adjustment in Instrument Panel, Gages and Console. Did you complete the repair? | Go to Step 5 | -- |
4 | Replace the IP compartment lamp and switch. Refer to Instrument Panel Courtesy Lamp Bulb Replacement . Did you complete the replacement? | Go to Step 5 | -- |
5 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |