The numbers below refer to the step numbers on the diagnostic table.
This step tests the output of the blower motor switch in each speed position and through each blower motor control circuit.
Test the circuit that did not illuminate the test lamp in Step 5.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The blower motor operates in at least one, but not all, speed positions. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the blower motor operate at the desired speed in each speed position? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate in each speed position? | Go to Step 7 | Go to Step 4 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 12 |
Important: Place the blower motor switch in the correct speed position for the control circuit that you are testing.
Does the test lamp illuminate in each speed position? | Go to Step 10 | Go to Step 6 | |
Test the applicable blower motor control circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 11 | |
7 |
Does the test lamp illuminate in each speed position? | Go to Step 9 | Go to Step 8 |
8 | Test the ground circuit of the blower motor resistor assembly for a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 10 |
9 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 13 |
10 | Inspect for poor connections at the harness connectors of the blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 14 |
11 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 15 |
12 | Repair the battery positive voltage circuit of the blower motor resistor assembly. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 16 | -- |
13 | Replace the blower motor. Refer to Blower Motor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 16 | -- |
14 | Replace the blower motor resistor assembly. Refer to Blower Motor Resistor Assembly Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 16 | -- |
15 | Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | Go to Step 16 | -- |
16 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |