Removal Procedure
- Remove the indicator.
- Raise and support the vehicle. Refer to
Lifting and Jacking the Vehicle
in General Information.
- Disconnect the three-way catalytic converter pipe. Refer to
Catalytic Converter Replacement
in Engine Exhaust.
- Remove the fluid filler
tube bracket bolt from the fluid filler tube bracket.
- Remove the fluid filler tube.
Installation Procedure
Important: Do NOT place the fluid filler tube seal on the fluid filler tube when
installing the tube or damage to the seal will result.
- Install the fluid filler tube seal in the transaxle.
- Position the fluid filler tube.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the fluid
filler tube bracket bolt through the fluid filler tube bracket.
Tighten
Tighten the bolt to 13 N·m (115 lb in).
- Connect the three-way catalytic converter pipe. Refer to
Catalytic Converter Replacement
in Engine Exhaust.
- Lower the vehicle.
- Install the indicator.
- Adjust the fluid level.
- Inspect for proper completion of the repairs.
- Inspect for proper fluid level.
- Inspect for fluid leaks.