Caution: Keep hands, tools, and clothing away from the electric engine coolant fans in order to help prevent personal injury. These fans are electric and can turn on whether or not the engine is running. The fans can start automatically with the ignition in the ON position.
13.1. | Bent or cracked cooling fan blades |
13.2. | Smoothness of the cooling fan blade mating surfaces |
13.3. | Remove burrs or other imperfections as necessary |
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the cooling fan nut to 6 N·m (53 lb in).
Tighten
Tighten the radiator bracket bolt to 10 N·m (89 lb in).
Tighten
Tighten the cooling fan shroud bolts to 6 N·m (53 lb in).