The Body Control Module (BCM) is connected to the Remote Control Door Lock Receiver by a communication circuit. This data link circuit is how the Remote Control Door Lock Receiver tells the BCM what functons to operate.
The BCM must be in the middle of receiving a message from the Remote Control Door Lock Receiver while in the Transmitter Programming mode.
The BCM detects a short to battery in the communication circuit.
The BCM stores DTC B3103 in memory.
• | A current DTC B3103 will clear if the short to ground in communication circuit is no longer detected by the BCM. |
• | A history DTC B3103 will clear after 100 consecutive ignition cycles if the condition for the malfunction is no longer present. |
• | A scan tool may be used to clear the DTC. |
If the DTC B3103 is a history DTC, the fault may be intermittent. Refer to Intermittents and Poor Connections.
The number(s) below refer to the step number(s) on the diagnostic table.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Remote Keyless Entry Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the test lamp illuminate? | -- | Go to Step 3 | Go to Step 4 |
Test the RFA Serial Data Link circuit for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 5 | |
4 | Inspect for poor connections at the harness connector of the Remote Control Door Lock Receiver. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 6 |
5 | Inspect for poor connections at the harness connector of the Body Control Module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 7 |
6 |
Important: All transmitters which are to be recognized by the Remote Control Door Lock receiver must be programmed in a single programming sequence. If the system is placed in program mode it will erase all previously programmed transmitters upon the receipt of the programming signal from the first transmitter Replace the Remote Control Door Lock Receiver. Refer to Receiver Replacement . Did you complete the replacement? | -- | Go to Step 8 | -- |
7 |
Did you complete the replacement? | -- | Go to Step 8 | -- |
8 |
Does the DTC reset? | -- | Go to Step 2 | System OK |