Engine Controls Schematics
OBD II Symbol Description Notice
Power Distribution Schematics
Ground Distribution Schematics
VCM Connector End Views

Circuit Description

The heated oxygen sensor (HO2S) is a sensor designed to create a voltage relative to the oxygen content in the engine exhaust stream. The control module supplies the HO2S with signal high and low circuits. Ignition voltage and ground are supplied to the HO2S heater by independent circuits. The oxygen content of the exhaust indicates when the engine is operating lean or rich. When the HO2S detects that the engine is operating rich, the signal voltage is high, and decreases the signal voltage as the engine runs leaner. This oscillation above and below the bias voltage, sometimes referred to as activity or switching, can be monitored with the HO2S signal voltage.

The HO2S contains a heater that is necessary in order to quickly warm the sensor to operating temperature. The heater also maintains the operating temperature during extended idle conditions. The HO2S needs to be at a high temperature in order to produce a voltage. When the HO2S reaches operating temperature, the control module monitors the HO2S bias, or reference, voltage. It also monitors the HO2S signal voltage for Closed Loop fuel control. During normal Closed Loop fuel control operation, the control module will add fuel, or enrich the mixture, when the HO2S detects a lean exhaust content. The control module will subtract fuel, or "lean-out" the mixture, when the HO2S detects a rich exhaust condition.

Certain vehicle models utilize an oxygen sensor behind the catalytic converter in order to monitor catalyst efficiency.

This diagnostic trouble code (DTC) determines if the HO2S is functioning properly. It checks for an adequate number of HO2S voltage transitions above and below the bias range of 300-600 mV. This DTC sets when the vehicle control module (VCM) fails to detect a minimum number of voltage transitions above and below the bias range during the test period. Possible causes of this DTC are:

    • An open or a short to voltage on either the HO2S signal or HO2S low circuits
    • A malfunctioning HO2S
    • A problem in the HO2S heater or its circuit
    • A faulty HO2S ground

This DTC determines if the HO2S heater circuit is functioning properly by monitoring the time required for the HO2S to reach the operating temperature. This DTC sets when the vehicle control module (VCM) fails to detect HO2S voltage transitions above and below the bias range within a specified time. Possible cause of this DTC are:

    • An open circuit in either the HO2S ignition feed or in the HO2S heater ground circuits
    • An HO2S heater element problem

Conditions for Running the DTC

Important: This test is void for this cold start if the system voltage remains outside the specified range for more than 4 seconds

    • The system voltage is between 11.7-17 volts.
    • The MAF is less than 27 g/s.
    • The engine run time is more than 2 seconds.
    • The ECT is less than 33°C (91°F).
    • The IAT is less than 33°C (91°F).
    • The difference between the ECT and IAT is 5°C (9°F) or less.

Conditions for Setting the DTC

The O2 sensor voltage remains within 150 mV of its startup voltage for 245 seconds after cold start.

Action Taken When the DTC Sets

    • The control module illuminates the malfunction indicator lamp (MIL) if a failure is detected during 2 consecutive key cycles.
    • The control module sets the DTC and records the operating conditions at the time the diagnostic failed. The failure information is stored in the scan tool Freeze Frame/Failure Records.

Conditions for Clearing the MIL or DTC

    • The control module turns OFF the MIL after 3 consecutive drive trips when the test has run and passed.
    • A history DTC will clear if no fault conditions have been detected for 40 warm-up cycles. A warm-up cycle occurs when the coolant temperature has risen 22°C (40°F) from the startup coolant temperature and the engine coolant reaches a temperature that is more than 70°C (158°F) during the same ignition cycle.
    • Use a scan tool in order to clear the DTCs.

Diagnostic Aids

Important: Never solder the HO2S wires. For proper wire and connection repair refer to Wiring Repairs or Connector Repairs in Wiring Systems.

An intermittent may be caused by any of the following conditions:

    • A poor connection
    • Rubbed through wire insulation
    • A broken wire inside the insulation

Thoroughly inspect any circuitry that is suspected of causing the intermittent complaint. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.

If a repair is necessary, refer to Wiring Repairs or Connector Repairs in Wiring Systems.

Test Description

The numbers below refer to the step numbers on the diagnostic table.

  1. As the heater warms the oxygen sensor to the operating temperature, the HO2S will output a voltage that is relative to the amount of oxygen in the exhaust. With the ignition ON and the engine OFF, the exhaust usually contains a high oxygen content. With the engine OFF, the HO2S voltage will usually decrease from the initial, or bias, voltage due to the high oxygen content.

  2. This step checks for proper HO2S heater ignition feed and ground supply.

  3. This step checks for proper VCM and signal circuit operation.

Step

Action

Values

Yes

No

1

Did you perform the Powertrain On-Board Diagnostic (OBD) System Check performed?

--

Go to Step 2

Go to Powertrain On Board Diagnostic (OBD) System Check

2

Important: The HO2S must be cool before you proceed with the diagnosis. The Ignition must remain OFF for at least one-half hour before proceeding with diagnosis.

  1. Connect the scan tool.
  2. Set up the scan tool with the proper vehicle identification information prior to turning ON the ignition.
  3. Turn ON the ignition, with the engine OFF.
  4. As quickly as possible, observe and record the HO2S voltage for the sensor that applies to this DTC.
  5. Monitor the HO2S voltage for 2  minutes.

Does the HO2S voltage increase or decrease from the initial voltage by at least the specified value?

150 mV

Go to Step 3

Go to Step 4

3

  1. The condition that set this DTC is not present. This DTC may have been set by:
  2. • An intermittently open or a high-resistance HO2S HIGH signal circuit or LOW circuit
    • An intermittently open or high-resistance HO2S heater ignition feed or ground circuit
    • Faulty HO2S or VCM connector terminal contact
    • A damaged HO2S
  3. Repair any of the above conditions as necessary.

Did you find a problem?

--

Go to Step 14

Go to Diagnostic Aids

4

  1. Turn OFF the ignition.
  2. Disconnect the HO2S connector for the sensor that applies to this DTC.
  3. Connect a test lamp between the HO2S heater ignition feed and the ground circuit terminals on the engine harness side.
  4. Turn ON the ignition, with the engine OFF.

Is the test lamp ON?

--

Go to Step 5

Go to Step 6

5

  1. Disconnect the test lamp.
  2. Jumper the HO2S LOW circuit terminal to a known good ground.
  3. Jumper the HO2S HIGH signal circuit terminal to a known good ground.
  4. Use a scan tool in order to monitor the HO2S voltage for the sensor that applies to this DTC.
  5. Ensure that the ignition is ON, with the engine OFF.

Is the HO2S voltage less than the specified value?

20  mV

Go to Step 8

Go to Step 7

6

  1. Connect the test lamp between the HO2S heater ignition feed circuit terminal on the engine harness side and a known good ground.
  2. Ensure the ignition is ON, with the engine OFF.

Is the test lamp ON?

--

Go to Step 9

Go to Step 10

7

  1. Turn OFF the ignition.
  2. Remove the jumpers from the VCM connector containing the HO2S HIGH and LOW circuits.
  3. Use a DMM in order measure the continuity of the HO2S HIGH signal circuit and then the HO2S LOW circuit between the VCM connector terminal and the HO2S connector terminal on the engine harness side.

Is the resistance less than the specified value?

5ohms

Go to Step 12

Go to Step 11

8

Replace the HO2S. Refer to Heated Oxygen Sensor Replacement .

Is the action complete?

--

Go to Step 14

--

9

Repair the open HO2S heater ground circuit. Refer to Wiring Repairs in Wiring Systems.

Is the action complete?

--

Go to Step 14

--

10

  1. Repair the lack of voltage on the HO2S heater ignition feed circuit. Refer to Wiring Repairs in Wiring Systems.
  2. If the fuse is blown, repair the short to ground on the circuit. A blown fuse or a lack of voltage to the fuse may cause other DTCs or symptoms.

Is the action complete?

5ohms

Go to Step 14

--

11

Repair the circuit that measured high resistance. Refer to Wiring Repairs in Wiring Systems.

Is the action complete?

--

Go to Step 14

--

12

  1. Check for proper VCM terminal contact.
  2. Repair the VCM terminals as necessary. Refer to Wiring Repairs in Wiring Systems.

Did you find a problem?

--

Go to Step 14

Go to Step 13

13

Important: The replacement VCM must be programmed.

Replace the VCM.

Refer to VCM Replacement/Programming .

Is the action complete?

--

Go to Step 14

--

14

Important: The HO2S must be cool before you proceed with diagnosis. The ignition must remain OFF for at least one-half hour before proceeding with diagnosis.

  1. Connect the scan tool.
  2. Set up the scan tool with the proper vehicle identification information prior to turning ON the ignition.
  3. Turn ON the ignition, with the engine OFF.
  4. As quickly as possible, observe and record the HO2S voltage for the sensor that applies to this DTC.
  5. Monitor the HO2S voltage for 2 minutes.

Does the HO2S voltage increase or decrease from the initial voltage by at least the specified value?

150 mV

Go to Step 15

Go to Step 4

15

Does the scan tool display any additional undiagnosed DTCs?

--

Go to applicable DTC

System OK