When you first turn ON the ignition, the supplemental restraint sensing and diagnostic module (SDM) performs tests to diagnose critical malfunctions within itself. Then the SDM performs the following continuous diagnostic tests on the deployment loops:
• | Deployment loop voltage out of range test |
• | Deployment loop resistance mearurement test |
If the voltage out of range test detects a short to voltage condition, the resistance measurement test for that deployment loop will not be performed.
• | Ignition 1 voltage is within the normal operating voltage range. |
• | Passenger frontal deployment loop is not open. |
• | Passenger frontal deployment loop is not shorted to voltage. |
• | Passenger frontal deployment loop is not shorted to ground. |
Passenger frontal deployment loop resistance is less than 1.3 ohms for 500 milliseconds.
The SDM commands ON the AIR BAG warning lamp via Class 2 serial data.
• | You can issue a CLEAR CODE command |
• | A history DTC will clear once 255 malfunction free ignition cycles have occurred |
The following can cause an intermittent condition:
• | A short between the passenger frontal high and the passenger frontal low circuits. |
• | A malfunctioning shorting bar on the supplemental restraint IP module 2-way connector. |
• | Refer to Testing for Intermittent Conditions and Poor Connections Testing for Intermittents and Poor Connections in Wiring Systems. |
The number(s) below refer to the step number(s) on the diagnostic table.
This step checks the IP/passenger inflator module in-line connector for physical damage.
This step checks to see if there is a malfunctioning supplemental restraint passenger inflator module.
This step determines if there is a short between passenger frontal high and low deployment circuits or if there is a malfunctioning SDM.
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the A Diagnostic System Check-SRS? | -- | ||||||||
Does connector exhibits any signs of corrosion, terminal damaged, or poor connections? | -- | |||||||||
3 | Replace the wiring harness side of in-line connector. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you complete the replacement? | -- | -- | |||||||
4 |
Is DTC retrieved as current? | -- | Go to Diagnostic Aids | |||||||
Is DTC retrieved as current? | -- | |||||||||
6 |
Did you complete the replacement? | -- | -- | |||||||
Is the measured resistance less than the specified value? | OL | |||||||||
8 | Locate and repair the short between high and low deployment circuits. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |||||||
9 | Replace the supplemental restraint sensing and diagnostic module (SDM). Refer to Supplemental Restraint Sensing and Diagnostic Module Replacement . Did you complete the replacement? | -- | -- | |||||||
10 |
Did you complete the action? | -- | System OK |