Diagnostic Instructions
Circuit Description
The fuel level sender changes resistance based on fuel level. The powertrain control module (PCM) monitors the signal circuit of the fuel level sender in order to determine fuel level. When the fuel tank is full, the sender resistance is low and the PCM
senses a low signal voltage. When the fuel tank is empty, the sender resistance is high and the PCM senses a high signal voltage. The PCM uses the signal circuit of the fuel level sender in order to calculate the total remaining fuel percentage in the tank.
The PCM sends the fuel level percent via the class 2 serial data circuit to the instrument cluster in order to control the fuel gage. The fuel level information is also used for misfire and evaporative emission (EVAP) diagnostics.
Reference Information
Schematic Reference
Connector End View Reference
Electrical Information Reference
Scan Tool Reference
Scan Tool Data List
Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the fuel level sensor. Install a signal generator and instrument panel tester between the signal circuit and the low reference circuit.
- Ignition ON, vary the resistance on the signal generator from 40-250 ohms. Verify that the scan tool Fuel Tank Level Remaining parameter displays the correct fuel level percent.
⇒ | If the fuel level percent is incorrect, test the signal circuit and the low reference circuit for an open/high resistance. If the circuits test normal, replace the PCM. |
- Ignition ON, vary the resistance on the signal generator from 40-250 ohms and monitor the fuel gage.
⇒ | If the gage is incorrect, replace the IPC. |
- If all circuits test normal, test or replace the fuel level sensor.
Repair Instructions
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.