GM Service Manual Online
For 1990-2009 cars only

Step

Action

Yes

No

Schematic Reference: Wiper/Washer Schematics

Connector End View Reference: Wiper/Washer Connector End Views

DEFINITION: The low washer fluid indicator always indicates low washer fluid or does not turn on with low washer fluid.

1

Did you review the Wiper/Washer System Description and Operation and perform the necessary inspections?

Go to Step 2

Go to Symptoms - Wiper/Washer Systems

2

Verify the fault is present.

Does the system operate normally?

Go to Testing for Intermittent Conditions and Poor Connections

Go to Step 3

3

  1. Turn OFF the ignition.
  2. Disconnect the washer fluid level switch connector.
  3. Turn ON the ignition.

Does the low washer fluid indicator illuminate for 60 seconds after the ignition is turned ON?

Go to Step 6

Go to Step 4

4

  1. Turn OFF the ignition.
  2. Connect a fused jumper wire from the washer fluid level switch signal circuit terminal in the washer fluid level switch connector to a good ground.
  3. Turn ON the ignition.

Does the low washer fluid indicator illuminate for 60 seconds after the ignition is turned ON?

Go to Step 5

Go to Step 7

5

  1. Turn OFF the ignition.
  2. Connect a fused jumper wire across the washer fluid level switch harness connector terminals.
  3. Turn ON the ignition.

Does the low washer fluid indicator illuminate for 60 seconds after the ignition is turned ON?

Go to Step 9

Go to Step 8

6

Test the washer fluid level switch signal circuit for a short to ground. Refer to Circuit Testing and to Wiring Repairs .

Did you find and correct the condition?

Go to Step 13

Go to Step 11

7

Test the washer fluid level switch signal circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs .

Did you find and correct the condition?

Go to Step 13

Go to Step 11

8

Repair the washer fluid level switch ground circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs .

Is the repair complete?

Go to Step 13

--

9

Inspect for poor connections at the washer fluid level switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs .

Did you find and correct the condition?

Go to Step 13

Go to Step 10

10

Replace the washer fluid level switch. Refer to Washer Pump Replacement .

Is the repair complete?

Go to Step 13

--

11

Inspect for poor connections at the instrument panel cluster (IPC). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs .

Did you find and correct the condition?

Go to Step 13

Go to Step 12

12

Replace the IPC. Refer to Control Module References for replacement, setup, and programming.

Is the repair complete?

Go to Step 13

--

13

Operate the system in order to verify the repair.

Did you correct the condition?

System OK

Go to Step 3