GM Service Manual Online
For 1990-2009 cars only

The generator does not require periodic lubrication. The rotor shaft is mounted on bearings. Each bearing contains a permanent grease supply. Periodically check the mounting bolts for tightness, and the drive belt tension. The drive belt is self-adjusting, within the operating limits of the tensioner. Refer to Engine Mechanical for tensioner information.

Removal Procedure

Important: Service the generator as a complete unit.


    Object Number: 1239071  Size: SH
  1. Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .
  2. Remove the drive belt. Refer to Drive Belt Replacement in Engine Mechanical - 3.5L.
  3. Remove the generator electrical connections.
  4. Remove the generator mounting nuts and bolts.
  5. Remove the generator.

Installation Procedure

    Notice: Refer to Fastener Notice in the Preface section.


    Object Number: 1239071  Size: SH
  1. Install the generator .
  2. Tighten

        • Tighten the bolts to 50 N·m (37 lb ft).
        • Tighten the nuts to 30 N·m (22 lb ft).
  3. Install the generator electrical connections.
  4. Install the drive belt. Refer to Drive Belt Replacement in Engine Mechanical - 3.5L.
  5. Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .