Important:
• When using the valve lifters again, install the lifters to their original
locations. • If camshaft replacement is required, the valve lifters must also be replaced.
Align the flat area on the top of the lifter with the flat area in the lifter guide bore. Push the lifter completely into the guide bore.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the valve lifter guide bolt to 12 N·m
(106 lb in).