Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Review the fog lamp operation and perform the necessary inspections. Did you complete the system review and inspection? | -- | Go to Step 2 | Go to Symptoms |
2 | Attempt to operate the fog lamp. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Remove the rear fog lamp relay. Do the rear fog lamps turn off? | -- | Go to Step 4 | Go to Step 5 |
4 | Repair the short to voltage in CKT 122 (RED) between the rear fog lamp relay and the rear fog lamp. Did you complete the repair? | -- | Go to Step 8 | -- |
5 | Disconnect the rear fog lamp switch connector. Does the rear fog lamp turn off? | -- | Go to Step 7 | Go to Step 6 |
6 | Repair the short to ground in CKT 1977 (YEL) between the rear fog lamp relay and the rear fog lamp switch. Did you complete the repair? | -- | Go to Step 8 | -- |
7 | Replace the rear fog lamp switch. Did you complete the repair? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |