Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: The center high-mounted stoplamp is inoperative or has only one bulb working, but the other stoplamps operate normally. | ||||
1 | Review the stoplamp operation and perform the necessary inspections. Did you complete the system review and inspection? | -- | Go to Step 2 | Go to Symptoms |
2 | Attempt to operate the stoplamps. Does the center high-mounted stoplamp operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Did you complete the repair? | -- | Go to Step 11 | Go to Step 4 |
4 |
Did the measurement equal battery voltage? | B+ | Go to Step 8 | Go to Step 5 |
5 | With the brakes applied, measure the voltage at cavity A of connector C419. Did the measurement equal battery voltage? | -- | Go to Step 7 | Go to Step 6 |
6 | Repair the open circuit (WHT) between splice S410 and connector C419. Did you complete the repair? | -- | Go to Step 11 | -- |
7 | Repair the open CKT 17 (WHT) between connector C419 and the connector for the center high mounted stoplamp. Did you complete the repair? | -- | Go to Step 11 | -- |
8 | At connector C419, test the continuity between ground and cavity B of connector C419. Did the test indicate continuity? | -- | Go to Step 9 | Go to Step 10 |
9 | Repair the open CKT 150 (BLK) between the center high mounted stoplamp socket and connector C419. Did you complete the repair? | -- | Go to Step 11 | -- |
10 | Repair the open CKT 150 (BLK) between connector C419 and splice S400. Did you complete the repair? | -- | Go to Step 11 | -- |
11 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: The center high-mounted stoplamp is inoperative, but the other stoplamps operate normally. | ||||
1 | Review the stoplamp operation and perform the necessary inspections. Did you complete the system review and inspection? | -- | Go to Step 2 | Go to Symptoms |
2 | Attempt to operate the stoplamps. Does the center high-mounted stoplamp operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | With the brakes applied, measure the voltage of CKT 17 (WHT) at connector C419 cavity A. Did the measurement equal battery voltage? | -- | Go to Step 5 | Go to Step 4 |
4 | Repair the open CKT 17 (WHT) between splice S410 and connector C419. Did you complete the repair? | -- | Go to Step 8 | |
5 | At connector C419, test the continuity between ground and cavity B of connector C419. Did the test indicate continuity? | -- | Go to Step 7 | Go to Step 6 |
6 | Repair the open CKT 150 (BLK) between connector C419 and splice S400. Did you complete the repair? | -- | Go to Step 8 | -- |
7 | Replace the center high-mounted stoplamp light-emitting diode assembly. Did you complete the repair? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |