Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Review the hazard lamp operation and perform the necessary inspections. Did you complete the system review and inspection? | -- | Go to Step 2 | Go to Symptoms |
2 | Attempt to operate the hazard lamps. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | At C200 terminal E8, test the voltage of the power supply wire for the hazard warning switch (CKT 1040 ORN). The terminal is accessible for testing without disconnection. Is battery voltage available at terminal E8? | B+ | Go to Step 5 | Go to Step 4 |
4 | Repair the open CKT 1040 (ORN) between the HAZARD fuse and connector C200 terminal E8. Did you complete the repair? | -- | Go to Step 10 | -- |
5 |
Did the test indicate battery voltage? | B+ | Go to Step 7 | Go to Step 6 |
6 | Replace the multifunction switch assembly which contains the hazard warning switch. Refer to Multifunction, Turn Signal and Hazard Switch Replacement - On Vehicle . Did you complete the repair? | -- | Go to Step 10 | -- |
7 | Attempt to operate the turn signals. Do the turn signals operate? | -- | Go to Step 8 | Go to Step 10 |
8 |
Did you locate and repair an open circuit? | -- | Go to Step 10 | Go to Step 9 |
9 | Replace the turn/hazard lamp flasher. Did you complete the repair? | -- | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |