Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Horns System Check performed? | -- | Go to Step 2 | Go to Horns System Check |
2 | Remove the horn relay from the socket. Do the horns continue to sound? | -- | Go to Step 3 | Go to Step 4 |
3 | Repair the short to voltage in CKT 29 (DK GRN) between the horn relay and the horns. Do the horns continue to sound? | -- | Go to Step 4 | Go to Horns System Check |
4 |
Does the test lamp light? | -- | Go to Step 5 | Go to Step 6 |
5 | Repair the short to ground in CKT 28 (BLK) between the horn relay and the horn switch. Do the horns continue to sound? | -- | Go to Step 6 | Go to Horns System Check |
6 | Connect the horn relay back into the socket. Does the horn continue to sound? | -- | Go to Step 7 | Go to Step 8 |
7 | Replace the horn relay. Do the horns continue to sound? | -- | -- | Go to Horns System Check |
8 | Replace the horn switch. Do the horns continue to sound? | -- | -- | Go to Horns System Check |