Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Instrument Cluster System Check performed? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 3 |
3 | Repair the open in CKT 39 (PNK) between splice S216 and the instrument cluster. Are all of the gauges operative? | -- | Go to Step 4 | |
4 | Connect an unpowered test lamp between cavity B13 for CKT 451 (BLK/WHT)/CKT 551 (TAN/WHT), and cavity B17 for CKT 39 (PNK) of the instrument cluster connector. Does the test lamp light? | -- | Go to Step 5 | Go to Step 6 |
5 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Are all of the gauges operative? | -- | -- | |
6 | Repair the open in CKT 451 (BLK/WHT)/CKT 551 (TAN/WHT) between the instrument cluster and ground G101. Are all of the gauges operative? | -- | -- |