Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 2 |
2 | Repair the open in CKT 840 (ORN) between the IP fuse block and the auxiliary power outlet. Is the auxiliary power outlet operative? | -- | System OK | Go to Step 3 |
3 | Connect a digital multimeter (DMM) between the auxiliary power outlet connector, cavity B for CKT 150 (BLK), and ground. Is continuity present? | -- | Go to Step 4 | Go to Step 5 |
4 | Replace the auxiliary power outlet. Is the auxiliary power outlet operative? | -- | System OK | Go to Step 5 |
5 | Repair the open in CKT 150 (BLK) between the auxiliary power outlet and ground G201. Is the repair complete? | -- | System OK | -- |