4L80-E Automatic Transmission Fluid Pressure Manual Valve Position
Switch (TFP Val. Position Sw.) Resistance Check
Step
| Action
| Value(s)
| Yes
| No
|
Important: Whenever the transmission 20-way connector is disconnected and the engine
is running, multiple DTCs will set. Clear any DTC codes after finishing the
procedure.
|
1
|
- Install the
J 39775
jumper harness on the transmission side of the 20-way connector.
- Using the
J 39200
digital multimeter (DMM) and the
J 35616-A
connector test adapter kit, measure the resistance from terminal N
to the transmission case.
Is the resistance greater than the value indicated?
| 50 kΩ
|
Go to Step 3
|
Go to Step 2
|
2
|
- Disconnect the automatic transmission (A/T) wiring harness assembly
from the automatic transmission fluid pressure (TFP) manual valve position
switch.
- Measure the resistance from terminal A of the TFP manual
valve position switch to the switch housing.
Is the resistance greater than the value indicated?
| 50 kΩ
|
Go to Step 15
|
Go to Step 16
|
3
| Measure the resistance from terminal R to the transmission
case.
Is the resistance greater than the indicated value?
| 50 kΩ
|
Go to Step 5
|
Go to Step 4
|
4
|
- Disconnect the A/T wiring harness assembly from the TFP manual
valve position switch.
- Measure the resistance from terminal B of the TFP manual
valve position switch to the switch housing.
Is the resistance greater than the value indicated?
| 50 kΩ
|
Go to Step 15
|
Go to Step 16
|
5
| Measure the resistance from terminal P to the transmission
case.
Is the resistance greater than the value indicated?
| 50 kΩ
|
Go to Step 7
|
Go to Step 6
|
6
|
- Disconnect the A/T wiring harness assembly from the TFP manual
valve position switch.
- Measure the resistance from terminal C of the TFP manual
valve position switch to the switch housing.
Is the resistance greater than the value indicated?
| 50 kΩ
|
Go to Step 15
|
Go to Step 16
|
7
|
- Start the engine, and let the engine idle.
- Set the parking brake.
- Place the gear selector in Drive (D4).
- Measure the resistance from terminal R to the transmission
case.
Is the resistance less than the indicated value?
| 200Ω
|
Go to Step 8
|
Go to Step
14
|
8
|
- Place the gear selector in Drive (D4).
- Measure the resistance from terminal P to the transmission
case.
Is the resistance less than the value indicated?
| 200Ω
|
Go to Step 9
|
Go to Step
14
|
9
|
- Place the selector in Low (D1).
- Measure the resistance from terminal N to the transmission
case.
Is the resistance less than the value indicated?
| 200Ω
|
Go to Step 10
|
Go to Step
14
|
10
|
- Place the gear selector in Low (D1).
- Measure the resistance from terminal P to the transmission
case.
Is the resistance greater than the value indicated?
| 50 kΩ
|
Go to Step 11
|
Go to Step 16
|
11
|
- Place the gear selector in REVERSE.
- Measure the resistance from terminal N to the transmission
case.
Is the resistance less than the value indicated?
| 200Ω
|
Go to Step 12
|
Go to Step
16
|
12
|
- Place the transmission in REVERSE.
- Measure the resistance from terminal P to the transmission
case.
Is the resistance greater than the value indicated?
| 50 kΩ
|
Go to step 13
|
Go to Step 16
|
13
|
- Place the gear selector in Manual Third (D3).
- Measure the resistance from terminal R to the transmission
case.
Is the resistance greater than the value indicated?
| 50 kΩ
| System OK
|
Go to Step 16
|
14
|
- Disconnect the A/T wiring harness from the TFP manual valve position
switch.
- Inspect circuits 1224, 1225, and 1226 of the A/T wiring
harness assembly for an open circuit.
Did you find a condition?
| --
|
Go to Step
15
|
Go to Step 16
|
15
| Replace the A/T wiring harness assembly. Refer to A/T
Wiring Harness Replacement .
Is the replacement complete?
| --
|
Go to Step
1
| --
|
16
|
- Replace the TFP manual valve position switch.
- Refer to Control Valve Body Replacement.
- Inspect the A/T wiring harness assembly.
Is the replacement of the TFP manual valve position switch complete?
| --
|
Go to Step 1
| --
|