Removal Procedure
- Remove the transmission
fluid pressure (TFP) manual valve position switch bolts and the TFP valve
position switch).
Important: The five o-rings should remain attached to the TFP valve position switch
(2).
- Remove the control valve
assembly bolts (4).
- Remove the fluid level indicator stop bracket.
- Remove the lube oil pipe retainer (7) and the clamp.
- Remove the lube oil pipe (5).
- Remove the manual shaft detent spring assembly (3).
- Remove the control valve assembly (2) which includes the following:
• | The accumulator housing assembly (1) |
• | The control valve assembly to the spacer plate gasket |
- Remove the manual valve
(1) from the control valve body to prevent any damage.
- Inspect the manual valve for nicks and burrs.
- Remove the spacer plate
to case gasket (2) from the case. The gasket may stick to the spacer plate.
- Remove the PWM screen (1) from the case passages.
- Remove the manual 2-1
band servo assembly (1).
- Remove the servo piston cushion spring (2).
- Remove the manual 2-1
band servo piston pin retainer ring (4).
- Remove the manual 2-1 band servo piston pin (1).
- Remove the manual 2-1 band servo piston seal (2).
Important: Do not use a magnet in order to remove the checkballs. Using a magnet
to remove the checkballs may magnetize the checkballs, causing metal particles
to stick.
- Remove the eight checkballs (nine checkballs for some models).
Control Valve Body Disassemble
- Remove the pressure control
solenoid clamp bolt (3) and clamp (2).
- Remove the pressure control solenoid (1).
- Remove the TCC PWM solenoid
retainer (5).
- Remove the TCC PWM solenoid (1).
- Remove the TCC regulator apply valve pin (4). Use a drill bit
to remove the spring pin.
- Remove the TCC regulator apply valve (2).
- Remove the TCC regulator apply valve spring (3).
- Remove the actuator feed
limit valve spring retainer (1).
- Remove the actuator feed limit valve spring (2).
- Remove the actuator feed limit valve (3).
- Remove the accumulator
valve bore plug retainer pin (1).
- Remove the accumulator valve bore plug (2).
- Remove the accumulator valve spring (3).
- Remove the accumulator valve (4).
- Remove the pressure control
solenoid valve fluid filter (1).
- Remove the low-reverse
ball valve seat pin (3).
- Remove the low-reverse ball valve seat (2).
- Remove the low-reverse ball valve (1).
- Remove the shift valve
fluid filter bore plug pin (3).
- Remove the shift valve fluid filter bore plug (2).
- Remove the shift solenoid valve fluid filter (1).
- Remove the 1-2 shift solenoid
valve bolt (5).
- Remove the 1-2 shift solenoid valve (4).
- Remove the 1-2 shift valve pin (3).
- Remove the 1-2 shift valve (2).
- Remove the 1-2 shift valve spring (1).
- Remove the 2-3 shift solenoid
valve bolt (5).
- Remove the 2-3 shift solenoid valve (3).
- Remove the 2-3 shift valve pin (4).
- Remove the 2-3 shift valve (2).
- Remove the 2-3 shift valve spring (1).
- Remove the 3rd-reverse
ball valve seat pin (7).
- Remove the reverse ball valve bushing (6).
- Remove the 3rd-reverse ball valve (5).
- Remove the 3rd ball valve bushing (4) and 3rd ball valve bushing
seal (3).
- Remove the 3-4 shift valve (2).
- Remove the 3-4 shift valve spring (1).
Control Valve Body Assemble
- Install the 3-4 shift
valve spring (1).
- Install the 3-4 shift valve (2).
- Install the 3rd ball valve bushing (4) and 3rd ball valve bushing
seal (3).
- Install the 3rd-reverse ball valve (5).
- Install the reverse ball valve bushing (6).
- Install the 3rd-reverse ball valve seat pin (7).
- Install the 2-3 shift
valve spring (1).
- Install the 2-3 shift valve (2).
- Install the 2-3 shift valve pin (4).
- Install the 2-3 shift solenoid valve (3).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the 2-3 shift solenoid valve bolt
(5).
Tighten
Tighten the bolt to 8 N·m (71 lb in).
- Install the 1-2 shift
valve spring (1).
- Install the 1-2 shift valve (2).
- Install the 1-2 shift valve pin (3).
- Install the 1-2 shift solenoid valve (4).
- Install the 1-2 shift solenoid valve bolt (5).
Tighten
Tighten the bolt to 8 N·m (71 lb ft).
- Install the shift solenoid
valve fluid filter (1).
- Install the shift valve fluid filter bore plug (2).
- Install the shift valve fluid filter bore plug pin (3).
- Install the low-reverse
ball valve (1).
- Install the low-reverse ball valve seat (2).
- Install the low-reverse ball valve seat pin (3).
- Install the pressure control
solenoid valve fluid filter (1).
- Install the accumulator
valve (4).
- Install the accumulator valve spring (3).
- Install the accumulator valve bore plug (2).
- Install the accumulator valve bore plug retainer pin (1).
- Install the actuator feed
limit valve (3).
- Install the actuator feed limit valve spring (2).
- Install the actuator feed limit valve spring retainer (1).
- Install the TCC regulator
apply valve spring (3).
- Install the TCC regulator apply valve (2).
- Install the TCC regulator apply valve pin (4).
- Install the TCC PWM solenoid valve (1).
- Install the TCC PWM solenoid valve retainer (5).
- Install the pressure control
solenoid valve (1) with the electrical connector facing away from the control
valve body.
- Install the pressure control solenoid clamp (2).
- Install the pressure control solenoid clamp bolt (3).
Tighten
Tighten the bolt to 8 N·m (71 lb in).
Installation Procedure
Tools Required
- Install the 8 checkballs
(9 Checkballs for some models) into the control valve body.
• | The checkball marked as number 2, is used on RCP, RDP, ZJP and
ZLP models only |
• | To hold the checkballs in place, use J 36850 |
- Install the PWM screen into the control valve body.
- Install a new manual 2-1
band servo piston seal (2) onto the manual 2-1 band servo piston (3).
- Install the manual 2-1 band servo piston pin (1) into the manual
2-1 band servo piston (3).
- Install the manual 2-1 band servo piston pin retainer ring (4).
- Install the manual 2-1
band servo piston cushion spring (2).
Important: Make certain that the tapered end of the manual 2-1 band servo piston
pin contacts the manual 2-1 band.
- Install the manual 2-1 band servo piston assembly (1).
- Install the manual valve
(1) into the control valve body.
- To aid in alignment and
assembly, install tool J 25025
.
- Install the control valve body gasket (6).
- Install the control valve body assembly (5). Attach the manual
valve to the detent lever while installing the control valve body assembly.
- Install the transmission
fluid pressure manual valve position switch (2).
- Install the transmission fluid pressure manual valve position
switch bolts (1) finger tight.
- Tighten the bolts in sequence
to 11 N·m (97 lb in).
- Remove J 25025
- Install the manual shaft
detent roller and spring assembly (3) and bolts (2 and 4).
- Install the two wiring harness clips (1) and bolts (2).
- Install the wiring harness clip (1) and bolts (2).
- Install the lube oil pipe (5) with the short end into the control
valve body.
- Install the lube oil pipe retainer (7) and the bolt (6).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the control
valve body bolts.
Tighten
Tighten the bolts sequentially to 11 N·m (97 lb in).
- Install the remaining control valve body bolts.
Tighten
Tighten the remaining bolts to 11 N·m (97 lb in).