Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Power Door Locks System Check performed? | -- | Go to Step 2 | |
2 | Check the condition of the PWR ACCY fuse A in the IP fuse block Is the fuse open? | -- | Go to Step 7 | Go to Step 3 |
3 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 8 |
4 | Connect a J 39200 between the power door lock relay connector, cavity D for CKT 150 (BLK), and ground. Is continuity present? | -- | Go to Step 5 | Go to Step 9 |
5 |
Is continuity present? | -- | Go to Step 6 | Go to Step 10 |
6 | Connect a J 39200 between the left front power door lock actuator motor connector, cavity B, and the power door lock relay connector, cavity E, for CKT 295 (GRY). Is continuity present? | -- | Go to Step 11 | Go to Step 12 |
7 | Repair the short to ground in CKT 540 (ORN). Refer to Wiring Repairs Is the repair complete? | -- | -- | |
8 | Repair the open in CKT 540 (ORN) between the IP fuse block and the power door lock relay. Refer to Wiring Repairs Is the repair complete? | -- | -- | |
9 | Repair the open in CKT 150 (BLK) between the power door lock relay and ground G201 or ground G200 on vehicles with upfitter provisions. Refer to Wiring Repairs Is the repair complete? | -- | -- | |
10 | Repair the open in CKT 294 (TAN) between the power door lock relay and splice S243. Refer to Wiring Repairs Is the repair complete? | -- | -- | |
11 | Replace the power door lock relay. Is the repair complete? | -- | -- | |
12 | Repair the open in CKT 295 (GRY) between the power door lock relay and splice S244. Refer to Wiring Repairs Is the repair complete? | -- | -- |