Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Power Windows System Check performed? | -- | Go to Step 2 | |
2 | Check condition of the PWR WDO fuse. Is PWR WDO fuse open? | -- | Go to Step 5 | Go to Step 3 |
3 |
Is continuity present? | -- | Go to Step 4 | Go to Step 6 |
4 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 8 |
5 | Repair the short to ground in CKT 343 (YEL) between the IP fuse block and the left front or right front door power side window switch. Refer to Wiring Repairs Is the repair complete? | -- | -- | |
6 | Repair the open in CKT 150 (BLK) between the left front door power side window switch and ground G201. Refer to Wiring Repairs Is the repair complete? | -- | -- | |
7 | Replace the left front door power side window switch. Refer to Front Side Door Window Switch Replacement Is the repair complete? | -- | -- | |
8 | Repair the open in CKT 343 (YEL) between the IP fuse block and splice S229. Refer to Wiring Repairs Is the repair complete? | -- | -- |