Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Is the voltage less than the specified value? | 10 V | Go to Step 2 | Go to Step 3 |
2 | Repair the open in CKT 39 (PNK) between the GAUGES fuse and the seat belt/lamps alarm module connector. Is the repair complete? | -- | System OK | -- |
3 |
Is the voltage less than the specified value? | 10 V | Got to Step 4 | Go to Step 5 |
4 | Repair the open in CKT 40 (ORN) between the HORN/DM fuse, cavity C 8 and the seat belt/lamps alarm module connector. Is the repair complete? | -- | System OK | -- |
5 | Use a J 39200 DMM to measure the voltage from the seat belt/lamps alarm module connector, cavity B 2 to B +. Is the voltage less than the specified value? | 10 V | Go to Step 6 | Go to Step 7 |
6 | Repair the open in CKT 250 (BLK) between the seat belt/lamps alarm module connector and G 200. Is the repair complete? | -- | System OK | -- |
7 | Use a J 39200 DMM to measure the voltage from the seat belt/lamps alarm module connector, cavity A 1 to B +. Is the voltage less than the specified value? | 10 V | Go to Step 8 | Go to Step 9 |
8 | Repair the open in CKT 8 (GRY) between the INSTR LPS fuse and the seat belt/lamps alarm module connector. Is the repair complete? | -- | System OK | -- |
9 | Replace the seat belt/lamps alarm module. Is the repair complete? | -- | System OK | -- |