GM Service Manual Online
For 1990-2009 cars only

Step

Action

Value(s)

Yes

No

1

  1. Turn the ignition switch to the RUN position.
  2. Remove the seat belt/lamps alarm module. Refer to Audible Warnings Component Views .
  3. Use a J 39200 DMM to measure the voltage from the seat belt/alarm module connector from cavity D 2 to a known good ground.

Is the voltage less than the specified value?

10 V

Go to Step 2

Go to Step 3

2

Repair the open in CKT 39 (PNK) between the GAUGES fuse and the seat belt/lamps alarm module connector.

Is the repair complete?

--

System OK

--

3

Use a J 39200 DMM to measure the voltage from the seat belt/lamps alarm module connector, cavity B 1 to ground.

Is the voltage less than the specified value?

10 V

Go to Step 4

Go to Step 5

4

Repair the open in CKT 40 (ORN) between the HORN/DM fuse and the seat belt/lamps alarm module connector.

Is the repair complete?

--

System OK

--

5

Connect a test light from the seat belt/lamps alarm module connector, cavity B 2 to B +.

Did the test light illuminate?

--

Go to Step 7

Go to Step 6

6

Repair the open in CKT 250 (BLK) between the seat belt/lamps alarm module connector and G 200.

Is the repair complete?

--

System OK

--

7

Connect a test light from the seat belt/lamps alarm module connector, cavity A 2 to B +.

Did the test light illuminate?

--

Go to Step 9

Go to Step 8

8

Repair the open in CKT 250 (BLK) between the seat belt/lamps alarm module connector and G 200.

Is the repair complete?

--

System OK

--

9

  1. Turn the headlamps switch to the PARK position.
  2. Use a J 39200 DMM to measure the voltage from the seat belt/lamps alarm module connector, cavity A 1 to ground.

Is the voltage less than the specified value?

10 V

Go to Step 10

Go to Step 11

10

Repair the open in CKT 8 (GRY) between the INSTR-LPS fused the seat belt/lamps alarm module connector.

Is the repair complete?

--

System OK

--

11

Replace the seat belt/lamps alarm module.

Is the repair complete?

--

System OK

--