Tools Required
J 39400-A Halogen
Leak Detector
Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
in Engine Electrical.
- Recover the refrigerant from the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Raise and support the vehicle. Refer to
Lifting and Jacking the Vehicle
in General Information.
- Remove the air baffle
bolts.
- Remove the air baffle.
- Remove the auxiliary evaporator
outlet tube to suction hose nut (2).
- Remove the evaporator outlet tube to suction hose bolt (1).
- Disconnect the suction hose from the evaporator outlet tube and
the auxiliary evaporator outlet tube.
Important: Cap or tape the open A/C lines and A/C refrigerant components immediately
to prevent system contamination.
- Cap or tape off the evaporator outlet tube and the auxiliary evaporator
outlet tube.
- Remove the suction hose
to compressor nut.
- Disconnect the suction hose from the compressor.
- Remove the suction hose.
- Discard the sealing washers.
- Cap or tape off the compressor suction port.
Installation Procedure
- Using a lint-free clean, dry cloth, carefully clean the sealing
surfaces of the A/C refrigerant hose and the A/C refrigerant component.
Important: Flat washer type seals do not require lubrication.
- Carefully slide the new sealing washer onto the compressor end of the
suction hose until seated.
- Install the suction hose.
- Remove the cap or tape from the compressor suction port.
- Connect the suction hose
to the compressor.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the suction hose to compressor nut.
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Remove the cap or tape from the evaporator outlet tube and the
auxiliary evaporator outlet tube.
- Install a new sealing washer at the suction hose to evaporator
outlet tube fitting.
- Install a new sealing washer at the suction hose to auxiliary
evaporator outlet tube fitting.
- Connect the suction hose
to the evaporator outlet tube and the auxiliary evaporator outlet fittings.
- Install the suction hose to evaporator outlet tube fitting bolt (1).
Tighten
Tighten the bolt to 16 N·m (12 lb ft).
- Install the auxiliary evaporator outlet tube to suction hose
nut (2).
Tighten
Tighten the nut to 16 N·m (12 lb ft).
- Install the air baffle.
- Install the air baffle bolts.
Tighten
Tighten the bolts to 20 N·m (15 lb ft).
- Lower the vehicle.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the component using J 39400-A
.
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
in Engine Electrical.