GM Service Manual Online
For 1990-2009 cars only

Instrument Panel Cluster (IPC) Gauges Read Zero at Times, Gauges Inoperative at Times (Reprogram IPC)

Subject:Instrument Panel Cluster (IPC) Gauges Read Zero at Times, Gauges Inoperative at Times (Reprogram IPC)

Models:2002 Chevrolet TrailBlazer, TrailBlazer EXT
2002 GMC Envoy, Envoy XL
2002 Oldsmobile Bravada



This bulletin is being revised to change the service procedure. Please discard Corporate Bulletin Number 02-08-49-004 (Section 08 -- Body and Accessories).


Condition

Some customers may comment that at times all the IPC gauges are inoperative or read zero at times.

Cause

The IPC cluster module receives information to position the gauges when the key is turned from OFF to ON/START. Random electrical interference with this data information on the serial data line may interrupt the receipt of the information by the IPC. When the IPC data information signal is compromised, the IPC will set the gauges to zero for that complete ignition cycle. The gauges may work properly on the next ignition cycle, if the ignition was off for approximately five minutes prior to the next ignition cycle.

Diagnostic Aid

With the Tech 2®, determine the IPC software part number using the following procedure.

  1. Connect the Tech 2 to the vehicle.
  2. Power up the Tech 2.
  3. From the main menu, Press Enter.
  4. Select F0: Diagnostics.
  5. Select the correct model year.
  6. Select: Ld Trk.
  7. Select F1: Body
  8. Select the proper vehicle line
  9. Select the proper name plate.
  10. Select the HVAC type.
  11. Select Instrument Panel Cluster.
  12. Select F4: ID Information.
  13. Select F1: Module Information 2
  14. If the IPC software part number is 09363270 or 15085477, re-program the IPC.

Correction

  1. Re-Program the IPC following normal SPS procedures (TIS Version 8.0 released July 2002, or newer).
  2. Clear all codes.
  3. Disconnect the Tech 2 and return the vehicle to the customer.

Warranty Information

For vehicles repaired under warranty, use:

Labor Operation

Description

Labor Time

N4199

Instrument Panel Cluster - Reprogram

0.4 hr