Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the audible warnings circuit operation and perform the necessary inspections? | -- | Go to Step 2 | |
2 |
Did the lights and chime operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Test the instrument cluster lights. Did the instrument cluster lights operate normally? | -- | Go to Step 5 | Go to Step 4 |
4 | Inspect the instrument cluster printed circuit for damage. Refer to Flat Wire Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 6 | Go to Step 5 |
5 | Replace the multifunction alarm. Refer to Multifunction Alarm Module Replacement . Did you complete the replacement? | -- | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |