Step | Action | Yes | No | ||||
---|---|---|---|---|---|---|---|
1 | Did you review the Backup Lamp Circuit Description and perform the necessary inspections? | Go to Step 2 | |||||
2 | Verify that the backup lamps are inoperative. Are the backup lamps inoperative? | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections | ||||
3 |
Is the resistance 0-2ohms? | Go to Step 5 | Go to Step 4 | ||||
4 |
Is the repair complete? | Go to Step 8 | -- | ||||
5 |
Does the test lamp illuminate with the ignition switch ON? | Go to Step 7 | Go to Step 6 | ||||
6 | Repair the open in the YEL wire between S211 and the backup lamp switch or the transmission range switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 8 | -- | ||||
7 | Repair the open in the RED wire between S318 and the backup lamp switch or the transmission range switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 8 | -- | ||||
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |